Product Details
Technical Specification
Model 500VA 650VA 800VA 1000VA 1200VA 1500VA
Output power 300W 390W 480W 600W 720W 900W
AC Input Voltage range 165V±5V~275V±5V / 90V-135V±3V
Output Voltage 220V±10% / 110V±10%
Output Frequency 50/60±6Hz
Waveform Square wave
Transfer Time Less than 6ms
DC voltage 12VDC 12VDC 12VDC 24VDC 24VDC 24VDC
Battery capacity 7AH*1 8AH*1 9AH*1 7AH*2 8AH*2 9AH*2
Backup time Full load >3min, half load >12min
Battery recharge time >8-12hours
Output overload The built-in current limiting circuit will automatically and rapidly lock out the machine so as to protect the inverter when overloaded
Automatic Charge When UPS off mode, UPS will automatically charge battery .
Battery low voltage When the battery voltage drops to a curtain value ,the UPS will automatically lock out the machine so as to protect the battery from over discharging
Withstand voltage strength 1500V1min peak surge through
Leakage current to ground <3.5mA
Temperature -20℃~40℃
Relative humidity 20~90%
Atmospheric pressure 86~106kpa