Model No. FC-300 |
|
|
|
Communications: |
1. Can set 6 voice alarm receiving phone #, 2 for CMS, 4 for private alarm receiving. |
2. Alarm type auto identify: After alarm triggered, LCD screen will display alarm zone #, alarm type, alarm icon and when it is connected to CMS, panel will report details of alarm to CMS. |
3. Compatible with CMS: Support Contact ID, Ademco 4+2 protocol. |
4. Remote Control: Enable to arm, disarm, listen to the spot, trigger siren and appliance etc via tel phone remotely. |
5. Vandal-proof function: If try to cut off the wire between wired detector and panel or cut off the tel line which connect to the panel will make alarm. |
6. Anti-tamper function: When someone try to remove panel deliberately, panel will make alarm immediately. |
7. Timing arm/disarm: Enable to set 4 group timer to arm/disarm. |
8. Timing testing: At preset time, panel will send signal to CMS to test the panel on-line status. |
9. Siren: The panel is with built-in siren and can enroll extension wireless siren. Both can be settled on/off when alarming. |
10. Wired/wireless zone real time monitoring: active the real time monitoring function, then if zone with trouble when doing arm/disarm operation, the panel will indicate zone fault. |
10. Can be connected with alarm repeater to prolong the wireless receiving distance. |
11. Tel-line off and wireless transfer function: panel make alarm or under arm status, but find out that tel-line off, panel will send signal to preset neighbour panel and the neighbour panel will report alarm instead. |
|
Automations: |
1. With voice indication all around the operation. |
2. LCD screen text and diagram display. |
3. Total 32 wireless zones, each zone enable learning code automatically or enter code manually on the keypad. |
4. Total 8 wired zones and can be compatible with N/O or N/C detector or sensor. |
5. Enable enroll total 8 wireless remote, wireless door bell, and unlimited quantity of one way wireless siren. |
6. Zone programmable: Each zone can be set as delay, instant alarm and can be modified. |
7. Enroll wireless device: wireless detector and remote address code can be enrolled automatically or manually and separately or simultaneously. |
8. Clock and event list: with built-in clock, can be set according to local time. |
9. Status inspection function: Enable record and inquiry 120 alarm event message including anti-tamper alarm, detector alarm, tel-line off alarm, arm/disarm, system setting, low battery alarm. And also can inquiry the zone number and alarm type. |
10. Password operation: Administrator password is for system programming and setting. User password is for commen operation. Both passwords can be modified. |
11. 4, 5 or 6 digits user code can be set for central monitoring system. |
12. Voice indication volume enable to adjust on the switch. |
13. The build-in siren can be set enable or disable when emergency key on the panel or remote is pressed. |
14. During the alarm receiving procedure the user should enter 4 digit user password to enter. This avoid others without permission to operate the panel. |
15. Zone type: robbing alarm, thief alarm, gas leak alarm, ambulance alarm, self-defined alarm, fire alarm and boundary alarm. |
|
|
Specifications: |
Input Power: |
12V/500mA |
Built-in rechargeable battery : |
7.2V/500mAH |
Static current : |
40mA/12V (exclude wire detector current) |
Panel Alarm current : |
<250mA/12V |
Frequency: |
433MHz |
Recording time : |
15s |
Weight: |
550g |
Alarm dial method : |
DTMF |
Trigger delay of wired zones: |
≥100ms |
Dimension: |
166*115*30mm |
|
|
|
|