運揚有限公司 WANCO LIMITED
運揚有限公司 WANCO LIMITED 


GS-Member

Since 2008

Language


Hipot Tester

Click On Image To View Large
  • Hipot Tester

  • TOS5101

  • Kikusui

  • 2017-04-18 16:32

  • 2017-05-02 15:52

Product Description

Hipot Tester



耐高溫測試儀


Model : TOS5101

 

 

 

The Kikusui TOS5101

 


* Specification

 


Output block

Applied Voltage 0 to 5/ 0 to 10 kV AC and DC

AC

Maximum Rated 500VA / 10 kV, 50 mA

Waveform Commercial line waveform

Voltage Regulation Max. 15% (for max. rated load to no load)

Switching Use of a zero turn-on switch

 

DC

Applied Voltage 50W / 10 kV, 5 mA

Ripple 100 Vp-p typ. at 10 kV, no load

200 Vp-p typ. at max. rated output

Maximum Rated Max. 3% (for max. rated load to no load)

 

Output Voltmeters

Analog Scale 10 kV full scale , AC/DC

Class JIS Class 2.5

Accuracy ±5% of full scale

AC Indication Mean value response / rms value scale

 

Digital Full Scale 5 kV/ 10 kV full scale

Accuracy ±1.5% of full scale

AC Response Mean value response / rms value display

 

Ammeter

Digital Accuracy ±(5% + 20μA) of upper cutoff current

AC Response Mean value response / rms value displayType of Judgement

 

Pass/fail Judgement Function

●FAIL judgement

*When current detected above upper cutoff current

*When current detected below lower cutoff current

(FAIL signal generated when FAIL judgement made)

● PASS judgement

*When set time has elapsed and no abnormality is

detected

Upper cutoff current setting range AC: 0.1 to 55 mA DC: 0.1 to 5.5 mA

Lower cutoff current setting range AC: 0.1 to 55 mA DC: 0.1 to 5.5 mA

Judgement Accuracy ±(5% of upper cutoff current + 20μA)

Current Detection Integration of current absolute value followed

by comparison with reference value.

Calibration With rms value of sine wave using a pure

resistance load.

No-load output voltage required

for detection

Approx. 970 V when set to 50 mA AC

Approx. 160 V when set to 5 mA DC

Test Time Setting Range 0.5 to 999 sec (±10 ms) (timer-off function

provided)

Accuracy ±20 ms

Line Voltage 100V±10%, 50/60 Hz (Nominal voltages of

110V, 120V, 220V, 230V and 240V

available as factory options.)

 

Power Requirements

for line voltage of 100 V Max. 50 VA under no-load conditions

/ Approx. 600 VA at rated load

for line voltage of 100 V to 200 V Max. 50 VA under no-load conditions

/ Approx. 600 VA at rated load

for line voltage of 220 V to 240 V Max. 50 VA under no-load conditions

/ Approx. 610 VA at rated load

Electromagnetic compatibility (EMC) *3 Conforms to the requirements of the

following directive and standard.*2

EMC Directive 2004/108/EC

EN 61326-1

EN 61000-3-2

EN 61000-3-3

Under following conditions

1. Used HV test leadwires which is

supplied.

2. No discharge in testing.

3. Used the shielded cable which length is

less than three meters when the SIGNAL

I/O is used.

 

Safty Conforms to the requirements of the following

directive and standard.

Low Voltage Directive 2006/95/EC

EN 61010-1 Pollution degree 2

U L1244( T h e U L - a p p r o v e d p r o d u c t s

with input voltage of 120VAC satisfy the

UL1244 standerd.)

Insulation resistance 30 MΩ or more (500 V DC)

Hipot 1390 VAC, 2 seconds [between the AC LINE and chassis]

1200 VAC, 1 second [UL-approved products only]

Environment Specification range : 5 °C to 35°C / 20 %rh to 80 %rh

Operable range : 0 °C to 40°C / 20 %rh to 80 %rh

Storage range : -20 °C to 70 °C / 80 %rh or less

Dimensions (maximum) 430[16.9 inch] W × 177[6.97 inch] (195[7.68 inch]) H × 370[14.6 inch] (450[17.7 inch]) D mm

 

Weight

Lie voltage of 100 V Approx. 21 kg (Approx. 46.30 lbs)

Line voltage of 100 V to 120 V Approx. 23 kg (Approx. 50.70 lbs)

Line voltage of 220 V to 240 V Approx. 24 kg (Approx. 52.91 lbs)

Accessories

High-voltage test lead TL01-TOS (max.allowablevoltage: 5 kV /1.5m)

TL03-TOS (max.allowablevoltage: 10 kV /1.5m)

 

Others 14-pin amphenol plug (assembled)



 




Quantity : 0      My Inquiry Basket